Recover the built-in default licenses with Setup Tool, SNMP tables or FCI
If the gateway has lost its default licenses, they can be recovered on different ways.

Preliminary note
Beginning with firmware release 6.1.1 the "easy licensing" method was implemented, which allows recovering by using the SNMP shell or the Setup Tool. From 7.9.1 onward it is possible via FCI, too. The procedure is described with a bintec R3000 gateway with release 7.9.1 patch 2, other models are configured identically. On the TR200 changes should be effected via FCI with release 7.9.1 onwards.

How to recover

Per Setup Tool


Please connect via Telnet, SSH or serial line with the gateway and log into. Then type in "setup" followed by [Enter]. Now "ADD" a new entry at menu "Licenses" as shown below:

R3400 Setup Tool                       Funkwerk Enterprise Communications GmbH
[LICENSE][ADD]                                                           r3400
_______________________________________________________________________________


          Serialnumber
          Mask                       65535
          Description                default easy licensing


                    SAVE                               CANCEL
_______________________________________________________________________________


Per table access

Please connect via Telnet, SSH or serial line with the gateway and log into. Then type in at prompt "biboAdmLicenseTable" followed by [Enter]:

r3400:> biboadmlicensetable

inx SerialNumber(rw)  Mask(rw)          Key(*rw)          State(-rw)
    SerialId(rw)      HwSerial(ro)      LicType(ro)

r3400:biboAdmLicenseTable> mask=65535 key=0
  0: biboAdmLicenseMask.0.15( rw):       1351
  0: biboAdmLicenseKey.0.15( rw):
r3400:biboAdmLicenseTable> biboadmlicensetable

inx SerialNumber(rw)  Mask(rw)          Key(*rw)          State(-rw)
    SerialId(rw)      HwSerial(ro)      LicType(ro)

  0 999999            1351                                ok
                                        0

  1 0                 0                 "DH9XW98LS7ZR1XM5 ok
    "R3BIPSFRFactory" "R3B140005490044" ipsec

  2 0                 0                 "3FED4WC0KHTGY11J ok
    "R3BE2500Factory" "R3B140005490044" e25


Per FCI

Please connect via web browser with the gateway and log into. Now switch the current view on top of the page to "SNMP Browser":




Open the group "administration" on the left hand and select the entry "biboAdmLicenseTable". Now add a "NEW" entry on the right hand with same values as shown below and then finish with "OK":



The default licenses of the delivering state of the gateway are now recovered. Verify this fact if necessary through Setup Tool or FCI requesting the license menu.