FEC Onlineservices
Configuration of Port Trunking between a funkwerk switch S1224p and a funkwerk switch S128p with FCI
This FAQ describes how to configure Port Trunking between a funkwerk S1224p and a funkwerk S128p with the graphic user interface FCI (Funkwerk Configuration Interface).

Scenario

Preliminary Note:
- To configure the switches please use only Microsoft Internet Explorer 6 or higher
- On both switches the same number of ports have to be trunked
- Software Release on S1224p and S128p: 1.03
- Up to 4 Ports can be bundled to a single Trunkgroup

1. funkwerk S1224p Configuration
Start your browser and log in the switch.
Select menu Port -> Trunking -> Aggregator Setting

You have to configure the following settings:
- Group ID: Trunk.2
- Work Ports: select Port 3 and Port 4 and press ADD to add them to Work Ports.

Afterwards confirm the configuration with Apply.
 


2. funkwerk S128p Configuration
Start your browser and log in the switch.
Select menu Port -> Port Trunk -> Aggregator Setting

You have to configure the following settings:
- Group ID: Trunk.2
- Work Ports: select Port 3 and Port 4 and press ADD to add them to Work Ports.



Afterwards confirm the configuration with Apply.
 


2013 bintec elmeg GmbH